Intelligent Measurement
Intelligent Measurement
- Categories:Technology Innovation
- Time of issue:2021-01-20 10:14:45
- Views:0
Description:
Information
YS87B Hihg-power Programmable Multifunctional Standard Source Ten New Functions Introduced
-
High resolution up to 20ppmm (0.002%), arbitrary setting of 5.5 bit output value
-
Short-term stability in the 15 minutes up to 50ppmm (0.005%)
-
Check-available T24AV meter, the output load current in the voltage range up to 800mA
-
Output of current range available to be expanded to 30A
-
New self-calibration function, any calibration point available for use immediately after the calibration
-
Each measuring range with 30 scale divisions and fixed-point value errors
-
Automatically the detect errors in each scale division and fixed-point value of the tested meter
-
Detectable rolling pin, with a scanning speed of ten scale marks
-
It can detect the needle rolling condition of the checked meter. With ten sweep speeds
-
The errors if the calibrated meter can be displayed in a conversion between "Reference Error" and "Relative Error"
YS118C Programmable Multifunctional Standard Power Source
YS118C programmable standard power source is a new intelligent power calibrator launched in 2006, characterized in high stability and easy operation, and is an ideal upgrade product for calibrating "AC/DC voltmeters, AC/DC ammeters, frequency meters, phase meters, AC/DC power meters and electricity transmitters". It features a phase angle closed loop and voltage closed loop, so as to ensure the low drift and annual stability. In addition, the instrument is equipped with a full-duplex RS232 interface and GPIB interface complying with IEEE488.2 Standards, to be easily connected with a PC, and applied for an automatic test system.
YS118C programmable standard power source is a new intelligent power calibrator launched in 2006, characterized in high stability and easy operation, and is an ideal upgrade product for calibrating "AC/DC voltmeters, AC/DC ammeters, frequency meters, phase meters, AC/DC power meters and electricity transmitters". It features a phase angle closed loop and voltage closed loop, so as to ensure the low drift and annual stability. In addition, the instrument is equipped with a full-duplex RS232 interface and GPIB interface complying with IEEE488.2 Standards, to be easily connected with a PC, and applied for an automatic test system.
ZL9 Intelligent LCR Tester
Basic Measurement Accuracy: 0.1% Test Frequency: 1MHz Allowable Tolerance: ± ±0.01%
Main Display Range:
Capacitance: 0.001-99999pF Resistance R: 0.01-999.9kΩ
Reactance X: 0.01Ω-9999kΩ Susceptance B: 0.1μS-999.99mS
Conductance G: 0.01μS-999.9mS Inductance L: 0.001-99999μH
Minus Volume Display Range: Quality Factor Q: 0.0001-999.9 import substitution
Dissipation Factor D: 0.0001-999.9 US GR1678
MMulti-way Power Automatic Test System
Multi-way power automatic test system is an automatic test system based on a GPIB bus, primarily used for automatic or semi-automatic electricity meter verification, and is composed of a PC with a PCI GPIB bus control interface board, a programmable multi-way switch, a tested source (or meter), a standard meter (or standard source) and other components. The electricity meters are widely used in various fields of national economy, including a large number of digital multimeters and multifunctional standard sources. In recent years, the quantity of units sent to the metrological department is increased each year and the accuracy requirements are also increasing, the formation of the GPIB bus automatic test system can achieve the automation of measurements and tests, improve the reliability of value transfer, and enable the measurement and test of the electricity meter to go to a new level, so as to promote the use of the electric instruments in the metering system.
Fine Air Particulate Matter Sampling Device (PM2.5)
NJ38 particulate sampler is applicable for collecting the air particulates with the median diameter of aerodynamic equivalent mass equal to 2.5μm, and is an ideal sampler for environmental monitoring stations to measure or analyze particulates.
3.1 particulate Cut Size: Da50=2.5±0.5μm
3.2 Geometric Standard Deviation of Collection Efficiency: σ g=1.5±0.1
3.3 Sampling Flow Operating Point: 100L/min
3.4 Sampling Flow Control Accuracy: ±8%
Raw Milk Freezing Point Tester
Overview
CHL-100 raw milk freezing point tester (hereinafter referred to as the tester) is a precision instrument to measure raw milk freezing point depression by using the freezing point method. Because the freezing point is a relatively stable physical quantity among those of raw milk, and it changes obviously after being mixed with water or other matters, generally, the freezing point increases by about 6m℃ after adding 1% of water, and the variation can be measured accurately with a tester. Therefore, measuring the freezing point of raw milk is a good method to test the water content of milk and is simple and easy for promotion.
The tester can be used to measure the freezing point values of raw milk samples, calculate the relative water content based on the standard value set, display the values on the display control panel, and immediately print test results, thus it is easy to use and features intuitive display.
Main Technical Performance Indicators
Temperature Measuring Range: 0.0000℃ to -1.0000℃
Temperature Measuring Resolution: 0.0001℃
Freezing Point Temperature Measuring Accuracy: less than ±4m℃
Sample Volume: 2.5±0.1ml
Testing Time: 2 to 3min
Tantalum Capacitor Automatic Test System
Tantalum capacitor automatic test system is composed of a GPIB bus controller, a ZL5 intelligent LCR tester, a NJ28 programmable leakage current tester, a NJ29 programmable multi-way switch, an air drying cabinet and system software. The system can be used not only for the automatic test of the leakage current, capacitance and loss of a group (40) of tantalum capacitors, but also for the test of aluminum electrolytic and other types of electrolytic capacitors, as well as the test of resistors and inductors. The system software is developed by using VB6.0 and will run in Windows 98 operating system, it characterized in a user-friendly and intuitive work dialogue interface, easy operation, automatic display and storage, editable test data, automatic data processing according to the requirements of the procedures and test data printing, and the users can easily query the test data. The system software is closely combined with GB7213-87 National Standards, and the test data can be converted to and from Excel files, to provide convenience for test data collating, analysis and processing. The tantalum capacitor automatic test system can improve the tantalum capacitor test efficiency and test quality and enhance the capacitor production and test technology, thus it is a high value-added integrated system product. And the system can be applied by manufacturers, scientific research departments or metrology departments.
Scan the QR code to read on your phone
Tel:021-55211350
E-mail:shangyisuo@126.com
Copyright © 2020 Shanghai institute of instrumentation All Rights Reserved. 沪ICP备190088688号 By: www. 300.cn